PVM; 45CC; 280 BAR; CW (RH); 1800 RPM; MTG FLNG SAE J744-101-2 (B 2-BOLT); SHAFT SAE B-B; STR KEYED ; PORTS SAE J518 FLNG; SAE AUX; PORT LOC SIDE; CNTRL PC; AUX MTG NONE;
Vickers
02-328991
Pumpen PVM –; 45 cc; 280 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-101-2 (B 2-BOLT); WELLE SAE B-B; STR BEFESTIGTE ; TORE SAE J518 FLNG; SAE ZUSATZ; PORTLOC SEITE; STEUERpc; ZUSATZMTG KEINE;
M/C: PVM045ER06CS02AAA2800000YA0A
Wunschliste
PVM; 45CC; 280 BAR; CW (RH); 1800 RPM; MTG FLNG SAE J744-101-2 (B 2-BOLT); SHAFT SAE B; STR KEYED; PORTS SAE J518 FLNG; SAE AUX; PORT LOC SIDE; CNTRL PC; AUX MTG NONE;
Vickers
02-334321
Pumpen PVM –; 45 cc; 280 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-101-2 (B 2-BOLT); WELLE SAE B; STR BEFESTIGTE; TORE SAE J518 FLNG; SAE ZUSATZ; PORTLOC SEITE; STEUERpc; ZUSATZMTG KEINE;
M/C: PVM045ER05CS02AAA28000000A0A
Wunschliste
PVM; 141CC; 230 BAR; CW (RH); 1800 RPM; MTG FLNG SAE J744-127-4 (C; 4-BOLT); SHAFT SAE C-C; STR KEYED ; PORTS SAE J518 FLNG; SAE AUX; PORT LOC SIDE; CNTRL PC; AUX MTG SAE C; 2-/4-BOLT 14T SPLINE;
Vickers
02-335221
Pumpen PVM –; 141CC; 230 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-127-4 (C; 2-Bolzen-; WELLE SAE CM; STR BEFESTIGTE ; TORE SAE J518 FLNG; SAE ZUSATZ; PORTLOC SEITE; STEUERpc; ZUSATZMTG SAE C; 2-/4-BOLT 14T KEIL;
M/C: PVM141ER10GS02AAA2300000EA0A
Wunschliste
PVM; 45CC; 280 BAR; CW (RH); 1800 RPM; MTG FLNG SAE J744-101-2 (B 2-BOLT); SHAFT SAE B; STR KEYED; PORTS SAE J514 TUBE; SAE AUX; PORT LOC SIDE; CNTRL PC; AUX MTG NONE;
Vickers
02-335272
Pumpen PVM –; 45 cc; 280 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-101-2 (B 2-BOLT); WELLE SAE B; STR BEFESTIGTE; SAE j514 Flanschanschlüsse; SAE ZUSATZ; PORTLOC SEITE; STEUERpc; ZUSATZMTG KEINE;
M/C: PVM045ER05CS01AAA28000000A0A
Wunschliste
PVM; 57CC; 280 BAR; CW (RH); 1800 RPM; MTG FLNG SAE J744-127-2(C; 2-BOLT); SHAFT SAE C; STR KEYED; PORTS SAE J518 FLNG; SAE AUX; PORT LOC SIDE; CNTRL PC; AUX MTG SAE A; 2-BOLT; 9T SPLINE ;
Vickers
02-335552
Pumpen PVM –; 57 cc; 280 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-127-2 (C; 2-Bolzen-; WELLE SAE C; STR BEFESTIGTE; TORE SAE J518 FLNG; SAE ZUSATZ; PORTLOC SEITE; STEUERpc; ZUSATZMTG SAE A; 2-BOLT; KEIL 9T ;
M/C: PVM057ER09ES02AAA2800000AA0A
Wunschliste
PVM; 63CC; 230 BAR; CW (RH); 1800 RPM; MTG FLNG SAE J744-127-2(C; 2-BOLT); SHAFT SAE C; STR KEYED; PORTS SAE J518 FLNG; SAE AUX; PORT LOC SIDE; CNTRL PC; AUX MTG SAE C; 2-/4-BOLT 14T SPLINE;
Vickers
02-335583
Pumpen PVM –; 63CC; 230 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-127-2 (C; 2-Bolzen-; WELLE SAE C; STR BEFESTIGTE; TORE SAE J518 FLNG; SAE ZUSATZ; PORTLOC SEITE; STEUERpc; ZUSATZMTG SAE C; 2-/4-BOLT 14T KEIL;
M/C: PVM063ER09ES02AAA2300000EA0A
Wunschliste
PVM; 131CC; 280 BAR; CW (RH); 1800 RPM; MTG FLNG SAE J744-152-4 (D; 4-BOLT); SHAFT SAE D; STR KEYED; PORTS SAE J518 FLNG; SAE AUX; PORT LOC SIDE; CNTRL PC; AUX MTG SAE C; 2-/4-BOLT 14T SPLINE;
Vickers
02-345085
Pumpen PVM –; 131CC; 280 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-152-4 (D; 2-Bolzen-; WELLE SAE D; STR BEFESTIGTE; TORE SAE J518 FLNG; SAE ZUSATZ; PORTLOC SEITE; STEUERpc; ZUSATZMTG SAE C; 2-/4-BOLT 14T KEIL;
M/C: PVM131ER13JS02AAA2800000EA0A
Wunschliste
PVM; 18CC; 280 BAR; CW (RH); 1800 RPM; MTG FLNG SAE J744-82-2 (A 2-BOLT); SHAFT SAE 19-1; STR KEYED; PORTS SAE J514 TUBE; SAE AUX; PORT LOC END; CNTRL PC; AUX MTG NONE;
Vickers
02-346335
Pumpen PVM –; 18 CC; 280 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-82-2 (A 2-BOLZEN); WELLE SAE 19-1; STR BEFESTIGTE; SAE j514 Flanschanschlüsse; SAE ZUSATZ; PORTLOC ENDE; STEUERpc; ZUSATZMTG KEINE;
M/C: PVM018ER02AE01AAA28000000A0A
Wunschliste
PVM; 45CC; 280 BAR; CW (RH); 1800 RPM; MTG FLNG SAE J744-101-2 (B 2-BOLT); SHAFT SAE B; STR KEYED; PORTS SAE J514 TUBE; SAE AUX; PORT LOC END; CNTRL PC LS   PLUG ORI; AUX MTG NONE;
Vickers
02-347735
Pumpen PVM –; 45 cc; 280 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-101-2 (B 2-BOLT); WELLE SAE B; STR BEFESTIGTE; SAE j514 Flanschanschlüsse; SAE ZUSATZ; PORTLOC ENDE; STEUERpc LS STECKER ORI; ZUSATZMTG KEINE;
M/C: PVM045ER05CE01AAC28110000A0A
Wunschliste
PVM; 45CC; 280 BAR; CW (RH); 1800 RPM; MTG FLNG SAE J744-101-2 (B 2-BOLT); SHAFT SAE B; STR KEYED; PORTS SAE J514 TUBE; SAE AUX; PORT LOC END; CNTRL PC; AUX MTG NONE;
Vickers
02-347736
Pumpen PVM –; 45 cc; 280 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-101-2 (B 2-BOLT); WELLE SAE B; STR BEFESTIGTE; SAE j514 Flanschanschlüsse; SAE ZUSATZ; PORTLOC ENDE; STEUERpc; ZUSATZMTG KEINE;
M/C: PVM045ER05CE01AAA28000000A0A
Wunschliste
PVM; 18CC; 70 BAR; CW (RH); 1800 RPM; MTG FLNG SAE J744-82-2 (A 2-BOLT); SHAFT SAE 19-1; STR KEYED; PORTS SAE J514 TUBE; SAE AUX; PORT LOC END; CNTRL PC; AUX MTG NONE;
Vickers
02-348486
Pumpen PVM –; 18 CC; 70 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-82-2 (A 2-BOLZEN); WELLE SAE 19-1; STR BEFESTIGTE; SAE j514 Flanschanschlüsse; SAE ZUSATZ; PORTLOC ENDE; STEUERpc; ZUSATZMTG KEINE;
M/C: PVM018ER02AE01AAA07000000A0A
Wunschliste
PVM; 18CC; 280 BAR; CW (RH); 1800 RPM; MTG FLNG SAE J744-82-2 (A 2-BOLT); SHAFT SAE A; STR KEYED ; PORTS SAE J514 TUBE; SAE AUX; PORT LOC END; CNTRL PC; AUX MTG NONE;
Vickers
123AL00011A
Pumpen PVM –; 18 CC; 280 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-82-2 (A 2-BOLZEN); ACHSE SAE A; STR BEFESTIGTE ; SAE j514 Flanschanschlüsse; SAE ZUSATZ; PORTLOC ENDE; STEUERpc; ZUSATZMTG KEINE;
M/C: PVM018ER01AE01AAA28000000A0A
Wunschliste
PVM; 131CC; 280 BAR; CW (RH); HI SPEED; MTG FLNG SAE J744-127-4 (C; 4-BOLT); SHAFT SAE C-C; STR KEYED ; PORTS SAE J518 FLNG; SAE AUX; PORT LOC SIDE; CNTRL PC; AUX MTG NONE;
Vickers
123AL00027A
Pumpen PVM –; 131CC; 280 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); HALLO GESCHWINDIGKEIT; MTG FLNG SAE J744-127-4 (C; 2-Bolzen-; WELLE SAE CM; STR BEFESTIGTE ; TORE SAE J518 FLNG; SAE ZUSATZ; PORTLOC SEITE; STEUERpc; ZUSATZMTG KEINE;
M/C: PVM131MR10GS02AAA28000000A0A
Wunschliste
PVM; 45CC; 280 BAR; CW (RH); 1800 RPM; MTG FLNG SAE J744-101-2 (B 2-BOLT); SHAFT SAE B; STR KEYED; PORTS SAE J518 FLNG; SAE AUX; PORT LOC SIDE; CNTRL PC LS   PLUG ORI; AUX MTG SAE B; 2-/4-BOLT; 13T SPLINE ;
Vickers
123AL00032A
Pumpen PVM –; 45 cc; 280 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-101-2 (B 2-BOLT); WELLE SAE B; STR BEFESTIGTE; TORE SAE J518 FLNG; SAE ZUSATZ; PORTLOC SEITE; STEUERpc LS STECKER ORI; ZUSATZMTG SAE B; 2-/4-Bolzen-; KEIL 13T ;
M/C: PVM045ER05CS02AAC2820000CA0A
Wunschliste
PVM; 74CC; 70 BAR; CW (RH); 1800 RPM; MTG FLNG SAE J744-127-4 (C; 4-BOLT); SHAFT SAE C-C; STR KEYED ; PORTS SAE J518 FLNG; SAE AUX; PORT LOC SIDE; CNTRL PC; AUX MTG NONE;
Vickers
123AL00037A
Pumpen PVM –; 74CC; 70 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-127-4 (C; 2-Bolzen-; WELLE SAE CM; STR BEFESTIGTE ; TORE SAE J518 FLNG; SAE ZUSATZ; PORTLOC SEITE; STEUERpc; ZUSATZMTG KEINE;
M/C: PVM074ER10GS02AAA07000000A0A
Wunschliste
PVM; 74CC; 230 BAR; CW (RH); 1800 RPM; MTG FLNG SAE J744-127-4 (C; 4-BOLT); SHAFT SAE C-C; STR KEYED ; PORTS SAE J518 FLNG; SAE AUX; PORT LOC SIDE; CNTRL PC; AUX MTG SAE A; 2-BOLT; 9T SPLINE ;
Vickers
123AL00038A
Pumpen PVM –; 74CC; 230 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-127-4 (C; 2-Bolzen-; WELLE SAE CM; STR BEFESTIGTE ; TORE SAE J518 FLNG; SAE ZUSATZ; PORTLOC SEITE; STEUERpc; ZUSATZMTG SAE A; 2-BOLT; KEIL 9T ;
M/C: PVM074ER10GS02AAA2300000AA0A
Wunschliste
PVM; 74CC; 280 BAR; CW (RH); 1800 RPM; MTG FLNG SAE J744-127-4 (C; 4-BOLT); SHAFT SAE C; STR KEYED; PORTS SAE J518 FLNG; SAE AUX; PORT LOC SIDE; CNTRL PC; AUX MTG NONE;
Vickers
123AL00040A
Pumpen PVM –; 74CC; 280 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-127-4 (C; 2-Bolzen-; WELLE SAE C; STR BEFESTIGTE; TORE SAE J518 FLNG; SAE ZUSATZ; PORTLOC SEITE; STEUERpc; ZUSATZMTG KEINE;
M/C: PVM074ER09GS02AAA28000000A0A
Wunschliste
PVM; 45CC; 280 BAR; CW (RH); 1800 RPM; MTG FLNG SAE J744-101-2 (B 2-BOLT); SHAFT SAE B; STR KEYED; PORTS SAE J514 TUBE; SAE AUX; PORT LOC SIDE; CNTRL PC; AUX MTG SAE B; 2-/4-BOLT; 13T SPLINE ;
Vickers
123AL00042A
Pumpen PVM –; 45 cc; 280 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-101-2 (B 2-BOLT); WELLE SAE B; STR BEFESTIGTE; SAE j514 Flanschanschlüsse; SAE ZUSATZ; PORTLOC SEITE; STEUERpc; ZUSATZMTG SAE B; 2-/4-Bolzen-; KEIL 13T ;
M/C: PVM045ER05CS01AAA2800000CA0A
Wunschliste
PVM; 98CC; 280 BAR; CW (RH); 1800 RPM; MTG FLNG SAE J744-127-4 (C; 4-BOLT); SHAFT SAE C; STR KEYED; PORTS SAE J518 FLNG; SAE AUX; PORT LOC SIDE; CNTRL PC; AUX MTG NONE;
Vickers
123AL00062A
Pumpen PVM –; 98CC; 280 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-127-4 (C; 2-Bolzen-; WELLE SAE C; STR BEFESTIGTE; TORE SAE J518 FLNG; SAE ZUSATZ; PORTLOC SEITE; STEUERpc; ZUSATZMTG KEINE;
M/C: PVM098ER09GS02AAA28000000A0A
Wunschliste
PVM; 131CC;  ; CW (RH); 1800 RPM; MTG FLNG SAE J744-127-4 (C; 4-BOLT); SHAFT SAE C-C; STR KEYED ; PORTS SAE J518 FLNG; SAE AUX; PORT LOC SIDE; CNTRL INDUSTRIAL (PC LS); AUX MTG SAE C; 2-/4-BOLT 14T SPLINE;
Vickers
123AL00085A
Pumpen PVM –; 131CC; ; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-127-4 (C; 2-Bolzen-; WELLE SAE CM; STR BEFESTIGTE ; TORE SAE J518 FLNG; SAE ZUSATZ; PORTLOC SEITE; CNTRL INDUSTRIAL (PC LS); ZUSATZMTG SAE C; 2-/4-BOLT 14T KEIL;
M/C: PVM131ER10GS02AAE0020000EA0A
Wunschliste
PVM; 98CC; 70 BAR; CW (RH); 1800 RPM; MTG FLNG SAE J744-127-4 (C; 4-BOLT); SHAFT SAE C; STR KEYED; PORTS SAE J518 FLNG; SAE AUX; PORT LOC SIDE; CNTRL PC; AUX MTG SAE A; 2-BOLT; 9T SPLINE ;
Vickers
123AL00086A
Pumpen PVM –; 98CC; 70 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-127-4 (C; 2-Bolzen-; WELLE SAE C; STR BEFESTIGTE; TORE SAE J518 FLNG; SAE ZUSATZ; PORTLOC SEITE; STEUERpc; ZUSATZMTG SAE A; 2-BOLT; KEIL 9T ;
M/C: PVM098ER09GS02AAA0700000AA0A
Wunschliste
PVM; 45CC; 70 BAR; CW (RH); 1800 RPM; MTG FLNG SAE J744-101-2 (B 2-BOLT); SHAFT SAE B; STR KEYED; PORTS SAE J518 FLNG; SAE AUX; PORT LOC SIDE; CNTRL PC; AUX MTG SAE A; 2-BOLT; 9T SPLINE ;
Vickers
123AL00087A
Pumpen PVM –; 45 cc; 70 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-101-2 (B 2-BOLT); WELLE SAE B; STR BEFESTIGTE; TORE SAE J518 FLNG; SAE ZUSATZ; PORTLOC SEITE; STEUERpc; ZUSATZMTG SAE A; 2-BOLT; KEIL 9T ;
M/C: PVM045ER05CS02AAA0700000AA0A
Wunschliste
PVM; 98CC; 230 BAR; CW (RH); 1800 RPM; MTG FLNG SAE J744-127-4 (C; 4-BOLT); SHAFT SAE C-C; STR KEYED ; PORTS SAE J518 FLNG; SAE AUX; PORT LOC SIDE; CNTRL PC; AUX MTG SAE A; 2-BOLT; 9T SPLINE ;
Vickers
123AL00093A
Pumpen PVM –; 98CC; 230 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-127-4 (C; 2-Bolzen-; WELLE SAE CM; STR BEFESTIGTE ; TORE SAE J518 FLNG; SAE ZUSATZ; PORTLOC SEITE; STEUERpc; ZUSATZMTG SAE A; 2-BOLT; KEIL 9T ;
M/C: PVM098ER10GS02AAA2300000AA0A
Wunschliste
PVM; 141CC; 230 BAR; CW (RH); 1800 RPM; MTG FLNG SAE J744-127-4 (C; 4-BOLT); SHAFT SAE C-C; 17T SPLINE ; PORTS SAE J518 FLNG; SAE AUX; PORT LOC SIDE; CNTRL PC LS   BLEED ORI; AUX MTG SAE B; 2-/4-BOLT; 13T SPLINE ;
Vickers
123AL00115A
Pumpen PVM –; 141CC; 230 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-127-4 (C; 2-Bolzen-; WELLE SAE CM; KEIL 17T ; TORE SAE J518 FLNG; SAE ZUSATZ; PORTLOC SEITE; STEUERpc LS BLUTORI; ZUSATZMTG SAE B; 2-/4-Bolzen-; KEIL 13T ;
M/C: PVM141ER12GS02AAB2311000CA0A
Wunschliste
PVM; 45CC; 280 BAR; CW (RH); 1800 RPM; MTG FLNG SAE J744-101-2 (B 2-BOLT); SHAFT SAE B; STR KEYED; PORTS SAE J518 FLNG; SAE AUX; PORT LOC SIDE; CNTRL PC; AUX MTG SAE A; 2-BOLT; 9T SPLINE ;
Vickers
123AL00121A
Pumpen PVM –; 45 cc; 280 BAR; RECHTS HERUM (RELATIVE FEUCHTIGKEIT); 1800 U/min; MTG FLNG SAE J744-101-2 (B 2-BOLT); WELLE SAE B; STR BEFESTIGTE; TORE SAE J518 FLNG; SAE ZUSATZ; PORTLOC SEITE; STEUERpc; ZUSATZMTG SAE A; 2-BOLT; KEIL 9T ;
M/C: PVM045ER05CS02AAA2800000AA0A
Wunschliste